Automotive Innovation ›› 2020, Vol. 3 ›› Issue (2): 111-122.doi: 10.1007/s42154-020-00096-z
Dong Hao1 · Xiaobing Wang1 · Yanyi Zhang1 · Renguang Wang1 · Guang Chen1 · Jun Li1
Dong Hao1 · Xiaobing Wang1 · Yanyi Zhang1 · Renguang Wang1 · Guang Chen1 · Jun Li1
摘要: Hydrogen safety is one of the most important safety indicators in fuel cell vehicles (FCVs) (unlike in other types of alternative energy vehicles). This indicator in FCVs is directly related to the user’s personal safety in daily vehicle usage. This paper analyzes the safety standards of FCVs in confned spaces. A sealed test chamber and an appropriate test method are developed to evaluate vehicle safety based on specifc test requirements. Two FCVs are subjected to static hydrogen leakage and hydrogen emission testing performed in a confned space. The results reveal that the hydrogen concentration in the vicinity of the vehicles approximates 0.0004% which is much lower than 1% while parked for 8 h during the hydrogen leakage test. In the hydrogen emission test under operating conditions, the concentration of the hydrogen gas emitted from the vehicles exceeds 2300 ppm in the vicinity, which requires careful consideration. Based on experiment and analysis, recommendations for the hydrogen safety standards of FCVs in confned spaces are proposed.